Ingenieurbüro für EMV

Dipl.-Ing. Heinz Lindenberger

English
Deutsch

Interactions

<
Rippelspannung-asc
Rippelspannung
Rippelspannung-Zoom

Simulating the Ripple-Voltage

In the present simulation, the modulation is 100%, the rotation frequency is 200 Hz   (= 3000 rpm for a 4-pole machine)

This results in a peak current of about 1000 A and an effective value of about 700 A


Combining HV-LE and HV + LE to HV-DC (the battery voltage at the inverter port) provides a variable for the FFT

The battery voltage with the Ripple-Voltage on the HV-line and the corresponding phase-current

The battery voltage with the Ripple-Voltage on the HV-line and the corresponding phase-current - zoomed

Rippelspannung-100Hz

The battery voltage with the Ripple-Voltage on the HV-line and the corresponding phase-current - at 100 Hz rotary frequency

Rippelspannung-Zoom-100Hz

The battery voltage with the Ripple-Voltage on the HV-line and the corresponding phase-current - zoomed - at 100 Hz rot. frequency

The maximum Ripple-Voltage results if the phase current and the modulation is maximum


Both with smaller modulation - in our example at 100 Hz rotation frequency - as well as with smaller phase current - in our example at 400 Hz rotation frequency - the Ripple-Voltage remains at smaller amplitudes


Rippelspannung-400Hz
Rippelspannung-Zoom-400Hz

The battery voltage with the Ripple-Voltage on the HV-line and the corresponding phase-current - at 400 Hz rotary frequency

The battery voltage with the Ripple-Voltage on the HV-line and the corresponding phase-current - zoomed - at 400 Hz rot. frequency